Airless spray equipment does not spray with air, but with paint itself under pressure of up to 200 bar. In order to spray evenly from the first stroke, the pump, hose and gun must be filled with material without air bubbles. This is called priming. The procedure is simple and after the second start you will do it by heart.
Before you plug in the machine
- The machine is turned off and unplugged , the pressure regulator is turned to minimum.
- The overflow valve (lever on the pump) is in the PRIME position – the paint returns through the return hose back to the bucket and there is no pressure in the hose.
- Prepare three buckets: clean water, an empty trash bucket, and paint.
- Work in protective glasses and gloves, and ensure ventilation indoors.
1. Folding
Screw the high-pressure hose to the pump outlet and the gun and tighten with both open-end wrenches - the connections must be tight, otherwise they will leak under pressure. If the suction hose is not factory-fitted, screw it to the suction part; you can put Teflon tape on its thread to prevent the pump from sucking in false air. Do not attach the nozzle yet. How to put everything together is shown in the Basic Assembly video.
2. Rinsing out the preservative liquid
New machines are tested in the factory and the pump is filled with corrosion protection fluid. It must be flushed out before the first paint.
- Immerse the suction hose in a bucket of water (in a suitable thinner for solvent-based paints), place the return hose in a waste bucket.
- Plug in and turn on the machine and turn the pressure regulator slightly. The pump will start to draw in and after a while, first a cloudy liquid will flow out of the return hose, then clear water.
- When clear water flows without bubbles, the pump is bled.
3. Filling the hose and gun
- Point the gun without the nozzle into the waste bucket and rest it against its edge.
- Turn the overflow valve to the SPRAY position and press the trigger. Air will come out first, then water.
- Hold the trigger until water flows in a steady stream. Release the trigger, lock the gun, and return the valve to the PRIME position.
4. Transition to color
Place the suction hose in the paint bucket and repeat the process: first through the return hose into the waste pipe until paint starts to flow instead of water (then put it in the paint bucket), then through the gun until it runs clear of paint. This will ensure that the remaining water ends up in the waste pipe, not on the wall.
5. Attaching the nozzle and adjusting the pressure
- Relieve pressure (procedure below) and lock the gun.
- Insert the nozzle into the butterfly (protective tip) with the arrow pointing forward – in the direction of spraying – and screw the tip tightly onto the gun.
- Switch to SPRAY and gradually increase the pressure. Test on cardboard until the strip has “tails” at the edges – streaks where there is less paint. The correct pressure is the lowest at which the strip is even. Higher pressure will only wear out the nozzle and seals faster and create unnecessary mist.
Hold the gun about 30 cm from the surface, perpendicular to it, and move your entire hand parallel to the wall. Squeeze the trigger only during the movement and release before the end of the stroke, overlapping adjacent strips by about half. For information on which nozzle to choose for which surface, see the article How to choose a nozzle and filter .
Pressure relief – always before cleaning and changing the nozzle
- Secure the gun trigger.
- Turn the pressure regulator to minimum and turn off the machine.
- Switch the overflow valve to the PRIME position.
- Unlock the gun and press the trigger into the bucket to release any remaining pressure. Lock the gun again.
Pressure may remain in the hose even after the machine is switched off. Never point the gun at yourself or other people. The pressurized paint stream can penetrate the skin. If this happens, seek medical attention immediately, even if the injury is minor.
When the machine does not suck in
- The suction hose is not submerged or the suction filter is clogged - clean or replace the suction filter .
- The suction hose connection is not tight and the pump is drawing air - tighten it or add Teflon tape.
- After a long period of standing, the suction valve may become stuck - start the machine in the PRIME position and lightly tap the suction part several times.
If you are unsure, call us. We offer free training with every machine and we are happy to advise you over the phone for the first start-up.